Disinfection Flow Rate - 16 mJ/cm2: --
- 30 mJ/cm2: --
- 40 mJ/cm2: --
- Rated Flow for NSF Std 55, Class A: 10 GPM (37.9 lpm)
Operating Parameters
- Max. Operating Pressure: 100 psi
- Ambient Air Temp: 32°F - 104° F
- Influent Water Temp: 36°F - 113°F
- Installation Orientation: Vertical
Electrical
- Voltage: 100-240 VAC
- Frequency: 50-60 Hz
- Max Current: 2.0 A
- Power Consumption: 120W
Dimensions
- Chamber: 22" x 4"
- Controller: 13" x 6-1/2" x 4-1/2"
- Inlet/Outlet: 1-1/4" MNPT x 1" FNPT Combo
- Shipping Weight: 25 lbs
Options
- Dynamic Flow Restrictor: Yes (included)
- Temperature Management Valve: Cool Touch Fan Included
- Solenoid Valve: Can be included
- COMMcenter Control Package: Can be included
Features
- Chamber Material: 316L SS
- UV Sensor: Yes
- Flow Meter: Yes
- Cool Touch Fan:
- Visual "Power On": Yes
- Visual Lamp Life Remaining: Yes
- Audible Lamp Failure: Yes
- Audible Lamp Replacement Reminder: Yes
- Sensor Reading Output (4-20 mA): Optional
Replacement Parts
- Lamp/Quartz Sleeve Kit: 602850-101
- UV Lamp Only: 602854
- Quartz Sleeve Only: 602974
- UV Sensor: 650580
- Controller: 650709-003