Viqua K+ (660002-R) Commercial UV System with Sensor, 80 GPM
Disinfection Flow Rates
These flow rates are based on 95% UVT Water
- 16 mJ/cm2: 120 GPM (454 lpm)
These flow rates are based on 95% UVT Water
- 16 mJ/cm2: 120 GPM (454 lpm)
- 30 mJ/cm2: 80 GPM (303 lpm)
- 40 mJ/cm2: 60 GPM (226 lpm)
- Adds state of the art UV technology to the K unit
- Continuous feedback of UV performance for added peace of mind
- Extends the range of the amalgam series with 2" MNPT connections
- Incorporates Cool-Touch fan technology
- 230W power allow for recommended flow rates up to 80 GPM
Whether you are looking to fit a small school or a large hotel, Viqua has an UV disinfection solution to meet your needs. Viqua's professional-grade equipment redefines reliability with rock solid performance under all environmental conditions.
Applications
- Schools, Daycares, eldercare, and healthcare facilities
- Schools, Daycares, eldercare, and healthcare facilities
- Cottages and camps
- Office and public buildings
- Restaurants, hotels and resorts
- Dairy and livestock
Replaces Obsolete UV Systems
- Sterilight SM80
     - 16 mJ/cm2: 120 GPM (454 lpm)
     - 30 mJ/cm2: 80 GPM (303 lpm)
     - 40 mJ/cm2: 60 GPM (226 lpm)
Operating Parameters
     - Max. Operating Pressure: 100 psi
     - Ambient Air Temp: 32°F - 104° F
     - Influent Water Temp: 34°F - 113°F
     - Installation Orientation: Vertical
Electrical
     - Voltage: 120-240 VAC
     - Frequency: 50-60 Hz
     - Max Current: 3.0 A
     - Power Consumption: 230W
Dimensions
     - Chamber: 41" x 4"
     - Controller: 13" x 6-1/2" x 4-1/2"
     - Inlet/Outlet: 2" MNPT 
     - Shipping Weight: 31 lbs
Options
     - Dynamic Flow Restrictor: No
     - Temperature Management Valve: CoolTouch Fan included
     - Solenoid Valve: Can be included
     - COMMcenter Control Package: Can be included
Features
     - Chamber Material: 316L SS
     - UV Sensor: Yes 
     - Flow Meter: No
     - Cool Touch Fan: Yes 
     - Visual "Power On": Yes
     - Visual Lamp Life Remaining: Yes
     - Audible Lamp Failure: Yes
     - Audible Lamp Replacement Reminder: Yes
     - Sensor Reading Output (4-20 mA): No
Replacement Parts
     - Lamp/Quartz Sleeve Kit: 602850-103
     - UV Lamp Only: 602856
     - Quartz Sleeve Only: 602976
     - UV Sensor: 650580
     - Controller: 660018-R
           
                 
 
                             
                             
                             
             
                 
                