The Optima HX series was designed with a sophisticated sizing program, combining Multipler Source Summation (MPSS) and Computational Fluid Dynamics (CFD), critical in calculating fluency rates, flow patterns and velocity distribution.
The series consists of 316L stainless steel treatment chamber and a stainless steel control panel in one integral unit for models with reactors up to 8" in diameter. Models HX 02 BDSU and above have a standard UL TYPE- 1 painted carbon steel control cabinet.
With low-pressure high-ouptput lamp (LPHO) technology, the HX lamp provides increased process performance and extended lamp life, while the systems compact size allows for a smaller footprint, maximizing installations flexibility. Single-ended (SE) HX lamps allow quick change-outs without tools.
The most basic differentiation within the HX product line is the designation "HX" or "HX-U". "HX" units come with the cylinder and electrical enclosure mechanically attached together. "HX-U" units have a remote enclosure that is suitable for wall mounting.
Two optional sample ports are available for obtaining water samples pre and post UV treatment chamber. Saintary sampling valves should be installed on the ports.
For heat sanitation above 170° F, stainless steel compression nuts and Viton elastomers are recommended. With these components, sanitization up to 250° F (121° C) is allowed in a non-operating state.
Applications
• Disinfection
• Ozone destruction
Markets
• Food & Beverage
• Life sciences
• Microelectronics
• Hospitals
• Hotels
Maximum Flow Rate |
Disinfection (@ 94% UVT) GPM | 1300 |
Disinfection (@ 99% UVT) GPM | N/A |
Number of UV Lamps (HX SE) | 12 |
Electrical Requirements |
Electrical Supply | 120/240V/50-60 Hz,Single Phase, 2 W + GND |
Oper. Power (Nominal Watts) | 1380 |
Ballast Type | Electronic |
Controller/Detector |
UV Vision 2000 G400 Series | Optional |
UV Temp. & Monitoring System | Optional |
Lamp Status Indicator | Standard |
Lamp Out Alert (LOA) | Optional |
Running Time Meter | Standard |
Hand/Off/Auto(HOA) | Optional |
4-20mA Output Signal | Optional |
Control Cabinet |
CC System Rating | C.S. - UL Type 1,S.S. - UL Type 3R |
Materials of Construction | C.S., Optional 304 SS |
Treatment Chamber |
Materials of Construction | 316L Stainless Steel |
Internal Surface Finish | Ra 32 (Ra 15Optional) |
Operating Temperature °F | Water: 41° - 104°,Ambient Air: 34° - 104° |
Max Oper. Pressure PSI | 150 |
Inlet/Outlet Flange Inches | 8 |
Hot Water Sanitize °F | 170° Available with S.S. comp. nuts only |
Sanitary Fittings | Optional |
Dimensions (For Reference Only) |
Overall Dimensions Inches H x W x D | 48.5 x 67 x 18.5 |