Dismiss ×

Free Shipping On Most Orders Over $150!!!!

My Account  |  0 item(s)    View Cart
Aquafine UV System HX 02 BDL, 78 GPM

Aquafine UV System HX 02 BDL, 78 GPM

Your Price:$5,218.00
Retail Price:$5,813.00
Your Savings:$595.00(10%)
Typically Ships in 2-10 Days
Part Number:HX-02-BDL

Choose Options

Cabinet Type
Connection Type
Gaskets/O-Rings
Monitoring System
Lamp Out Alert
Hand/Off/Auto (Remote Start/Stop
Interior Surface Finish
Sample Ports

Feature:

2055
Aquafine UV System HX 02 BDL, 78 GPM

The Optima HX series was designed with a sophisticated sizing program, combining Multipler Source Summation (MPSS) and Computational Fluid Dynamics (CFD), critical in calculating fluency rates, flow patterns and velocity distribution.

The series consists of 316L stainless steel treatment chamber and a stainless steel control panel in one integral unit for models with reactors up to 8" in diameter. Models HX 02 BDSU and above have a standard UL TYPE- 1 painted carbon steel control cabinet.

With low-pressure high-ouptput lamp (LPHO) technology, the HX lamp provides increased process performance and extended lamp life, while the systems compact size allows for a smaller footprint, maximizing installations felxibility. Single-ended (SE) HX lamps allow quick change-outs without tools.

The most basic differentiation within the HX product line is the designation "HX" or "HX-U". "HX" units come with the cylinder and electrical enclosure mechanically attached together. "HX-U" units have a remote enclosure that is suitable for wall mounting.

Two optional sample ports are available for obtaining water samples pre and post UV treatment chamber. Sanitary sampling valves should be installed on the ports.

For heat sanitation above 170° F, stainless steel compression nuts and Viton elastomers are recommended. With these components, sanitization up to 250° F (121° C) is allowed in a non-operating state.

Applications
• Disinfection
• Ozone destruction

Markets
• Food & Beverage
• Life sciences
• Microelectronics
• Hospitals
• Hotels

Maximum Flow Rate
Disinfection (@ 94% UVT) GPM78
Disinfection (@ 99% UVT) GPM90 
Number of UV Lamps (HX SE)2

Electrical Requirements
Electrical Supply120/240V/50-60 Hz,Single Phase, 2 W + GND
Oper. Power (Nominal Watts)360
Ballast TypeElectronic


Controller/Detector
UV Vision 2000 G400 SeriesN/A
UV Temp. & Monitoring SystemOptional
Lamp Status IndicatorStandard
Lamp Out Alert (LOA)Optional
Running Time MeterStandard
Hand/Off/Auto(HOA)Optional
4-20mA Output SignalOptional

Control Cabinet
CC System RatingC.S. - UL Type 1,S.S. - UL Type 3R for remote "U" Only
Materials of Construction304 S.S. / C.S.,Optional 304 SS

Treatment Chamber
Materials of Construction316L Stainless Steel
Internal Surface FinishRa 32 (Ra 15Optional)
Operating Temperature °FWater: 41° - 104°,Ambient Air: 34° - 104°
Max Oper. Pressure PSI150
Inlet/Outlet Flange Inches2
Hot Water Sanitize °F170° Available with S.S. comp. nuts only
Sanitary FittingsOptional

Dimensions (For Reference Only)
Overall Dimensions Inches H x W x D15 x 68 x 12










Related Items

Recently Viewed Items